Designed for power applications in North America

Use in control cabinets for the North-American market requires specific testing and certification of the components. In the case of power applications, they are subject to the UL 2237 standard. binder’s 823 and 824 series of compact cable connectors have been developed according to this standard.

binder, a leading supplier of industrial circular connectors, introduces the 823 and 824 series of cable connectors that are intended for use on the North-American continent. The K- and L-coded M12 products particularly aim at power applications and feature screw clamp terminations. They meet the requirements of the industry-relevant protection degree IP67, i.e. they are designed to be dust-tight and protected against temporary submersion.

K and L coding for industrial power applications
In industrial automation, the transmission of high electrical power via compact M12 components has become a fundamental requirement. The K coding indicates 5-pin connectors that are particularly suitable for power supply in AC applications, such as drives or frequency converters, with up to 630 V(AC) and up to 12 A. DC compact drives, decentralized I/O modules and various other DC-powered automation components connected to fieldbus systems are among the target applications of the likewise 5-pin connectors with L coding. They are designed for rated voltages up to 63 V(DC) and for rated currents up to 16 A.

UL 2237 background
Electromechanical interfaces on control cabinets intended for the North-American market require approvals in accordance with the UL 2237 and UL 2238 standards. While UL 2238 specifies cable assemblies and connectors for signal transmission, UL 2237 sets additional requirements for the power segment – for example, for the power supply in drives. It contains specifications for testing connectors, cables and cable glands as well as safety elements. One of the special features of UL 2237 is the so-called Grounding (Bonding) Path Current Test: Depending on the connection cross-section, the protection earth (PE) path must withstand a current of 190 A (AWG 16) or 300 A (AWG 14) over a period of four seconds without breaking. For AC applications, a so-called abnormal overload test is also mandatory: a test with 1.5 times the rated current, which is considered to be passed if the PE path fuse does not blow.

823 and 824 series product details
The binder product series 823 and 824 include both male and female cable and angled connectors for rated voltages of 630 V(AC) at rated currents of 12 A (K-coding; pin count 4+PE) and 63 V(DC) at 16 A (L-coding; pin count 4+FE – functional earth), respectively. They feature M12x1 threads, 8-mm to 13-mm cable outlets and screw clamp terminals. In order to meet the requirements of UL 2237, the threaded ring is electrically connected to the PE contact. UL 2237 certification is currently being prepared.

Über die Franz Binder GmbH & Co. Elektrische Bauelemente KG

binder is a family-owned business that is shaped by traditional values. Based in Neckarsulm, Germany, it is one of the leading specialists in the area of circular connectors. binder has been synonymous with the highest quality since 1960. We work with 45 distribution partners on five continents and employ 1,800 staff worldwide. The binder group is comprised of the binder headquarters, 16 affiliated companies, two systems providers and an Innovation and Technology Centre.

Firmenkontakt und Herausgeber der Meldung:

Franz Binder GmbH & Co. Elektrische Bauelemente KG
Rötelstraße 27
74172 Neckarsulm
Telefon: +49 (7132) 325-0
Telefax: +49 (7132) 325-150
http://www.binder-connector.de

Ansprechpartner:
Patrick Heckler
Category Leader Brand Communication
Telefon: +49 (7132) 325-448
Fax: +49 (7132) 325-150
E-Mail: p.heckler@binder-connector.de
Für die oben stehende Pressemitteilung ist allein der jeweils angegebene Herausgeber (siehe Firmenkontakt oben) verantwortlich. Dieser ist in der Regel auch Urheber des Pressetextes, sowie der angehängten Bild-, Ton-, Video-, Medien- und Informationsmaterialien. Die United News Network GmbH übernimmt keine Haftung für die Korrektheit oder Vollständigkeit der dargestellten Meldung. Auch bei Übertragungsfehlern oder anderen Störungen haftet sie nur im Fall von Vorsatz oder grober Fahrlässigkeit. Die Nutzung von hier archivierten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Eine systematische Speicherung dieser Daten sowie die Verwendung auch von Teilen dieses Datenbankwerks sind nur mit schriftlicher Genehmigung durch die United News Network GmbH gestattet.

counterpixel