Level measurement for cement clinker coolers

In cement production, the heart of the system is the rotary kiln, and the corresponding cooling system that follows. The efficient operation of these two systems together is critical to maintain efficiency and profitability in the cement manufacturing process. With operating temperatures exceeding up to 1300°C, the measurement of important parameters, such as the level of clinker on the cooling grates, is fraught with problems. Traditional, intrusive level measurement technologies simply cannot last in such a harsh environment.

To be cost efficient, the airflow to the clinker cooler must be regulated to the proper amount for the mass of the clinker present on the cooler grates. This requires an accurate level measurement of the clinker. Berthold‘s noncontact and nonintrusive radiometric level measurement technology provides an accurate and reliable clinker level measurement while operating outside of this extremely high temperature environment. The high degree of accuracy, stability and repeatability provided with this level measurement ensures high production rates, optimal efficiency, and superior product quality.

Detector for extreme operating environments

The clinker is cooled as it is discharged from the rotary kiln onto a moving grate through which air is forced. The cooling is regulated by the feed rate and the amount of airflow. The quality of the clinker is directly affected by the cooling rate.

Cooling too slowly results in larger crystaline structure, which requires more energy to complete the grinding process and can decrease product quality. Increasing airflow to the cooler ensures rapid cooling but also results in high energy costs and inefficiencies in other parts of the process. With an accurate measurement of the clinker level, the proper amount of clinker present on the cooler grates can be regulated. This leads to an optimized process and therefore generates cost savings.

Whether it is the proven two-wire system using remote transmitters or the integrated field devices with HART or Bus protocol, Berthold’s level gauges provide patented technology ensuring long-term stability and temperature stability. This achieves a longlasting measurement stability that withstands even strong ambient temperature

changes (up to 0.002% per °C). Berthold‘s level measurement systems are therefore the proven solution for this application.

These are the advantages of Berthold’s radiometric level measurement used for the cement clinker cooler process:

  • Accurate and reliable measurement of clinker level
  • Energy savings through process optimization
  • Low maintanance cost
  • Free of wear and maintenance
  • No re-calibration due to unmatched stability and aging compensation
  • Not exposed to harsh process conditions due to external mounting
  • Lowest possible source activity through extreme sensitive detector design

For further information please visit this link:
https://www.berthold.com/en/level-for-cement-clinker-coolers/

Über die BERTHOLD TECHNOLOGIES GmbH & Co. KG

As a world technology leader in the field of radiometric measuring systems, Berthold products convince with outstanding measuring performance and reliability. The main fields of application are, for example, in chemical & polymers (etc. fertilizer industry), steel and power plants, mining & mineral processing, waste & recycling, refineries, paper, glass and as well as in the food industry (etc. sugar beets). In addition, microwave measuring systems for the determination of moisture and concentration belong to our extensive portfolio. The production of high-quality measuring systems for industry and research began more than 70 years ago in Bad Wildbad in the Black Forest.

Firmenkontakt und Herausgeber der Meldung:

BERTHOLD TECHNOLOGIES GmbH & Co. KG
Calmbacher Straße 22
75323 Bad Wildbad
Telefon: +49 (7081) 177-0
Telefax: +49 (7081) 177-100
http://www.berthold.com/process-control/

Ansprechpartner:
Diana Keppler
Marketing / Process Control
Telefon: +49 (7081) 177-170
E-Mail: diana.keppler@Berthold.com
Für die oben stehende Pressemitteilung ist allein der jeweils angegebene Herausgeber (siehe Firmenkontakt oben) verantwortlich. Dieser ist in der Regel auch Urheber des Pressetextes, sowie der angehängten Bild-, Ton-, Video-, Medien- und Informationsmaterialien. Die United News Network GmbH übernimmt keine Haftung für die Korrektheit oder Vollständigkeit der dargestellten Meldung. Auch bei Übertragungsfehlern oder anderen Störungen haftet sie nur im Fall von Vorsatz oder grober Fahrlässigkeit. Die Nutzung von hier archivierten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Eine systematische Speicherung dieser Daten sowie die Verwendung auch von Teilen dieses Datenbankwerks sind nur mit schriftlicher Genehmigung durch die United News Network GmbH gestattet.

counterpixel