New Release 4.0 of EMVA 1288 Standard for Camera Characterization

The EMVA Standard 1288 for objective characterization of industrial cameras, which is successfully used worldwide, has a successor in the new Release 4.0, which now takes into account the rapid development of camera and image sensor technology. The release candidate was published on March 16 and the detailed standard texts can be viewed here.

Until the previous Release 3.1 dated back December 2016, the application of the EMVA 1288 standard with a simple linear model was limited to cameras with a linear response and without any pre-processing. While this model is being continued with some improvements in the ’Release 4.0 Linear’, a new module ‘Release 4.0 General’ has been added in the latest release. With it, the characterization of a non-linear camera or a camera with unknown pre-processing is possible even without any model due to the universal system-theoretical approach of the EMVA 1288 standard. Just as with the linear camera model, all application-related quality parameters can be measured in this way. Depending on the camera characteristics, the evaluation can now be applied according to the linear or general model.

In addition, Release 4.0 includes numerous expansions to characterize the latest generation of image sensors and cameras according to the application. The most important of these are:

  • Extended wavelength range from UV to SWIR range.
  • Raw data of any given image acquisition modality can now be characterized according to the standard.
  • The versatile and universal analysis tools of the EMVA 1288 standard can also be applied to quantities calculated and derived from multiple channels. For polarization image sensors, these are, for example, the degree of polarization and the polarization angle.
  • Inhomogeneities are measured in detail and now decomposed into column, row, and pixel variations. They can now be determined with a new method at all intensity levels from just two captured images.
  • Optionally, cameras with optics or with illumination as given by the position of the exit pupil of the optics for which the image sensor was designed can be measured according to the standard. Thus, the standard is now also suitable for image sensors with pixels shifted towards the edge.
  • A more suitable measure for the linearity of the characteristic curve is introduced.

After publication of the release candidate, the new Release 4.0 will automatically replace the old Release 3.1 after a three months period (therefore by mid-June) if no objections are submitted to the EMVA during this period and if objections can be resolved.

Along with the new version of the standard, the EMVA has prepared an extensive training program. Two- or three-day training programs for the new Release 4.0 will be held regularly in near future in cooperation with EMVA member companies. The new training program will also continue the successfully introduced certification program at expert level. This is intended for anyone who wants to acquire the necessary knowledge to perform EMVA 1288 measurements themselves and understand the measurement results in detail, whether in the development of new cameras, in quality control, or to understand exactly how a camera behaves for a specific application.

Über European Machine Vision Association

The EMVA is a not for profit organization, open to all, which is owned by its members who represent over 130 companies, institutes, and organizations, originating from within Europe, North America, and Asia. The association seeks to represent the interests of its members and promote the vision industry in general, but also encourage cooperation and standardization. The EMVA hosts several important standards used throughout the machine vision industry including the GenICam series used to provide a consistent, device independent interface to machine vision hardware, the EMVA1288 standard used for bench-marking performance of industrial cameras, and the newly initiated Open Optics Camera Interface (OOCI) standard which addresses the connectivity of camera lenses within a machine vision system, and the new emVISION initiative addressing standardization within embedded vision systems. To find out more visit the web site www.emva.org.

Firmenkontakt und Herausgeber der Meldung:

European Machine Vision Association
Ronda Santa Eulalia 37, nave 13
E08780 Palleja – Barcelona
Telefon: +34 (93) 1807060
Telefax: +34 (93) 1807060
http://www.emva.org

Ansprechpartner:
Andreas Breyer
Marketing
Telefon: +34 (93) 1807060
Fax: +34 (93) 1807060
E-Mail: press@emva.org
Für die oben stehende Pressemitteilung ist allein der jeweils angegebene Herausgeber (siehe Firmenkontakt oben) verantwortlich. Dieser ist in der Regel auch Urheber des Pressetextes, sowie der angehängten Bild-, Ton-, Video-, Medien- und Informationsmaterialien. Die United News Network GmbH übernimmt keine Haftung für die Korrektheit oder Vollständigkeit der dargestellten Meldung. Auch bei Übertragungsfehlern oder anderen Störungen haftet sie nur im Fall von Vorsatz oder grober Fahrlässigkeit. Die Nutzung von hier archivierten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Eine systematische Speicherung dieser Daten sowie die Verwendung auch von Teilen dieses Datenbankwerks sind nur mit schriftlicher Genehmigung durch die United News Network GmbH gestattet.

counterpixel